Explore is Sift’s workspace for visualizing and investigating high-rate time series telemetry. Use it to load data from Assets, Runs, and Families, arrange Panels, create Calculated Channels, annotate events, and share your analysis.

Data sources

A data source defines the telemetry context for an Explore session. It determines which Channels are available for analysis.

Data source replacement

A data source can be replaced mid-session without rebuilding the Panel layout.

Channels

Channels are the individual telemetry signals available for plotting. The Channels tab lists the Channels in the selected data sources, organized in a Channel tree by default. Explore does not support plotting or displaying bytes Channels.

Channel views

The Channels tab displays Channels in one of two views: Channel tree or Channel list. Channel tree is the default view. It organizes Channels hierarchically under their data source: a Run, Asset, or Family. Each Run shows its start time and duration, and each Channel shows its unit. Channel list shows a flat list of all Channels.

Contains data in range filter

The Contains data in range filter shows only the Channels in the Channels tab that contain data in a UTC date range. Open it from Filter Channels. You can combine it with text search and metadata filters.

Channel list refresh

Explore caches the Channels that the Channels tab lists. To load the latest Channels, click Refresh channel list, which clears the cache and reloads the list.

Channel plotting

Select or drag a Channel from the Channels tab onto a Panel to plot it. A data source must be selected before Channels are available. The Plot Channel to a new option in the Channel’s right-click menu plots the Channel to a new Panel of the selected Panel type. For example, select Time series to plot an enum or boolean Channel to a Time Series Panel instead of the default Enum Panel.

Calculated Channels

Calculated Channels are derived signals created by applying CEL expressions to raw Channel data. The Calculated Channels tab lists the Calculated Channels associated with the selected data source. You can also create Calculated Channels from this tab, so you can define a new signal without leaving Explore.

Calculated Channel types

A Calculated Channel you create in Explore is either temporary or saved. A temporary Calculated Channel exists only for the current session. A saved Calculated Channel persists across sessions. To create a saved Calculated Channel, turn on Save to Asset in the Calculated Channel fields.

Calculated Channel fields

In the Calculated Channels tab, click to open the Create Calculated Channel panel. The panel applies a CEL expression to raw telemetry data to create a custom metric.

Panel Configurations

A Panel Configuration saves a Panel’s Channel selections, axis mappings, color scales, hidden states, and styling for reuse on other Runs and Assets. The Panel Configurations tab shows configurations with at least one Channel name that matches the selected data source.

Panel Configuration operations

Panel Configuration fields

To save a Panel’s setup as a Panel Configuration, click Create new Panel Configuration in the Panel Configurations tab and then select the Panel to save. You can also select Save configuration as… in the Panel’s Open Panel Settings. Both open the Save Configuration As… dialog.

Annotations

Annotations mark specific times or time ranges in a Run. You can plot them on the Time Series Panel only and use them as T-0 alignment points for Run comparison. The Annotations tab groups Annotations by data source and Rule.

Annotation types

Annotation fields

In the Annotations tab, click Create new Annotation to open the Add Annotation panel. Select Phase or Data Review in the panel to set the Annotation type.

Annotation plotting

Click Plot all in the Annotations tab to plot every Annotation onto the Time Series Panel. Plot all does not plot Annotations inside a collapsed Rule folder. To plot the Annotations in a specific Rule folder regardless of its collapsed state, right-click the folder and select Plot all Annotations. This does not apply if the outer Annotation group containing the folder is itself collapsed.

Annotation caching

Explore caches Annotations. If an Annotation you created does not appear when you reopen an Explore view, or you can’t select or search for it, click in the Channels tab or in a Panel’s toolbar to reload the Annotations.

Metrics for an Annotation’s time range

A Metrics Panel calculates statistics over its own time range. To limit the statistics to an Annotation, open the Metrics Panel’s Open Panel Settings, click Update Time in the Time section, and enter the Annotation’s Start and End in From and To. Lock to Selection in the Metrics Panel keeps the Panel on that time range.

File Viewer tab

The File Viewer tab lists the files attached to each selected Run, grouped by Run. To display a file, open it in a File Viewer Panel. Files attached to an Asset do not appear. To upload a file to a Run, click Upload file in the Run’s row. Filenames must be unique per Asset. Click to filter the list by file name, file type (image, video, audio, or other), uploader, or Run.

Live mode

Live mode monitors real-time telemetry as it streams into Sift. LIVE in the Explore toolbar controls Live mode. All Panel types support Live mode. Live mode is compatible with Panel sync: when both are active, all synced Panels advance together as new data arrives. Set Live Data Refresh Settings and Live Data Scroll Behavior in General settings. In Live mode, Sift continuously polls for new data. To load older data that arrived late, such as backfilled timestamps, see Data loading and refresh. In Live mode, live Rules are not rendered; alerts appear as toast notifications.

Panel sync

Click SYNC in the Explore toolbar to turn Panel sync on or off. Syncing aligns the time range across multiple Panels. Adjusting the time window in one Panel updates all synced Panels. Panel sync also changes how the Time Slider moves Panels.

Time range and timezone

Click TIME in the Explore toolbar to set the timezone, alignment mode, and time range. To set the timezone that new Panels use, see Default Timezone in General settings.

Range controls

Range controls are in the Explore toolbar and apply to the Time Series, FFT, and Scatter Plot Panels.

Ad hoc Run from selection

An ad hoc Run is a Run created from a time window of an Asset or an existing Run plotted in a Time Series Panel. For how it differs from a Run, see Runs and ad hoc Runs.

Panel from selection

Explore creates a new Panel from a time window selected in a Time Series Panel.

User settings

User settings let you define personal default display preferences for Explore across two areas: general settings that apply to all Panels, and default settings per Panel type. Defaults apply to your account only. Individual Panel settings can still be overridden at any time. User settings are stored in the browser and do not carry over to other computers. Clearing the browser cache resets all User settings to their defaults. Open User settings from User Settings in the Explore toolbar.

General settings

The following settings are available under User Settings and apply globally across all new Panels in Explore.

Chart type settings

Default settings can be configured per Panel type. Select a Panel type from the Chart Type Settings dropdown to configure its defaults. Settings vary by Panel type and correspond to the individual Panel settings for each type. All Panel types are supported.

WebGL traces

WebGL traces is a setting for Time Series Panels. It renders traces with GPU-accelerated WebGL instead of the default ECharts renderer, which reduces slowdowns when a Panel displays many or high-frequency Channels. To turn it on, click User Settings in the Explore toolbar and select Timeseries from the Chart Type Settings dropdown. Turn on WebGL traces in the Panel Behavior section, and click Save.

Saved Explorations

A Saved Exploration is a named snapshot of an Explore session, including its Panels and their settings, layout, data sources, compare settings, time range, and draft Calculated Channels. Opening a Saved Exploration restores that session. Saved Explorations are listed on Run and Asset overview pages and can be associated with a Rule.

Saved Exploration fields

Click SAVE in the Explore toolbar to save a new Saved Exploration, or to save changes to the open one.

Save dropdown options

Click on the SAVE button in the Explore toolbar to open the SAVE dropdown. The Saved Explorations section of a Run or Asset overview page lists only the Saved Explorations for that Run or Asset. Select a row to open it in Explore.

Rule association

Associate Saved Exploration in the Rule form links a Saved Exploration to the Rule. The list shows only your own Private Saved Explorations, plus all Public ones. To open the associated Saved Exploration, open a Report that evaluates the Rule. In Rules, click View in Explore in the Rule’s row, then select View in Saved Exploration. The Report keeps a read-only copy of the associated Saved Exploration, which anyone who can view the Report can open, even if the original is Private. Changes to the original do not update the copy. To keep edits to the copy, save it as a new Saved Exploration.

Saved Exploration visibility

Visibility controls who sees a Saved Exploration in Saved Explorations lists. Set it in the Saved Exploration fields, or change it later with Edit Saved Exploration in the Save dropdown. Click SHARE in the Explore toolbar to generate a URL that captures the current state of Explore. Opening the URL restores Explore in the state it was shared.

Time Slider

The Time Slider spans the full width of Explore and gives you a single visual reference for where every Panel sits in time. Use it to see how each open Panel relates to the full range of available data and to track your position as you move across Panels.

Time Slider sync behavior

The Time Slider tracks the selected Panel. Drag a Panel’s time range on the Time Slider to update that Panel, or change the Panel’s time range to update its position on the Time Slider. SYNC in the Explore toolbar changes the number of Panels that the Time Slider affects.

Time Slider context menu

Right-click the Time Slider to open this context menu.

Page time range fields

Right-click the Time Slider and select Set page time range to open the Update Time Range (UTC) dialog.

Panels

A Panel displays Channel data in Explore as one Panel type, such as Time Series or Table.

Panel types

Panel layout

You can add, split, and reposition Panels in Explore. To add a Panel, click in the Panel tabs and select a Panel type. An Exploration with no Panels shows the Select panel type grid instead. To split a Panel, right-click its tab and select Split up, Split down, Split left, or Split right. The split duplicates the Panel in that direction, and the new Panel is configured separately. Panels can be moved to the top, bottom, left, or right of Explore.

Data loading and refresh

Panels load data on demand and cache it to reduce repeated queries. Sift caches data as soon as it loads into a Panel, except the most recent 2.5 to 7.5 minutes, which Sift always fetches live to allow for late-arriving data. When Live mode is off, Sift fetches data in response to Panel interactions. The Table Panel follows the same behavior as you scroll. To re-fetch cached data that changed after it first loaded, click Clear cache and reload in a Panel’s toolbar. For example, it loads older timestamps that an upstream system backfilled after you opened the view. Clear cache and reload works in all Panel types.

Time alignment

Time alignment synchronizes multiple Runs to a shared reference point (T-0) for direct comparison. Set it in the Alignment list in a Panel’s Time-Alignment settings tab. A relative alignment has a default alignment method, which you can override for each Run.

Bulk axis and style assignment

Group By in the Channel tab of Panel settings styles several Channels at once. Select an attribute, such as unit or Run, to apply settings to every Channel that shares it, or All Channels to apply them to every Channel in the Panel. Available in Time Series, FFT, Stat, and Enum Panels. Only Time Series and FFT Panels include Y-axis assignment.

Numeric Channel display format

Choose how numeric Channel values display in Time Series and Table Panels: decimal, hexadecimal, or binary. Set the format per Channel in the Channel tab of Panel settings.

Panel settings

Settings are organized into tabs, except in the Metrics and File Viewer Panels, and are independent per Panel.

Time Series

Table

Histogram

FFT

Metrics

The Metrics section includes the following metrics.

Stat

Enum

Geo Map

Scatter Plot

File Viewer

Panel-specific behavior

Time Series

Metrics

Stat

Enum

Geo Map

Scatter Plot

File Viewer

Export options

Certain Panel toolbars include an Export data button. Clicking it opens a dropdown; the available options depend on the Panel type. Exports run in the background. Export scope differs by Panel type:

Dynamic URLs

Use dynamic URLs to open Explore with preconfigured telemetry data. By navigating to the /explore route with query parameters, you can automatically load specific Runs or Assets, Channels, Panel types, and optional time ranges, allowing users to open the exact data needed for analysis without manual setup. For example, the following URL opens a Time Series Panel with a single Channel on a single Run:

URL structure

Use the /explore route with the required query parameter method=single to launch Explore with preconfigured data. Additional query parameters define Runs or Assets, Channels, Panel type, and optional time range. Construct the URL using the following format:

URL parameters

Axis prefixes

In the Time Series Panel, Channels can be plotted on multiple Y-axes by adding an axis prefix before the Channel name or UUID. If no prefix is provided, the Channel plots on the default axis L1. Axis prefixes are case-sensitive and work with both Channel names and UUIDs.

Scatter Plot role prefixes

In the Scatter Plot Panel, assign each Channel to an axis or visual encoding using a role prefix before the Channel name or UUID. The following tables list the role prefixes and the rules that apply to them.

Geo Map role prefixes

In the Geo Map Panel, assign each Channel to a coordinate or visual encoding using a role prefix before the Channel name or UUID. The following tables list the role prefixes and the rules that apply to them.

Channel selection by Panel type

When a dynamic URL lists Channels, each Panel type displays only the Channels it supports. Channels of an incompatible data type are ignored. For example, the Histogram, FFT, Scatter Plot, Geo Map, and Metrics Panels do not display string Channels, so a string Channel passed to one of them is dropped. The Histogram Panel displays a single Channel. If more than one Channel is provided, the first compatible Channel is used and a warning appears.